Diesel-Electric Engine Set

  • Revolving field, single bearing, brushless, direct drive centrifugal blower.
  • Class F insulation system per NEMA MGI-I.65 and BS 2757. The insulation systems, per Classes F and H, are impregnated for operation in severe environments where salt fog and chemical.
  • Rotor: Dynamically balanced assembly, direct coupled to engine by a flexible drive disc complete amortisseur winding to help minimize voltage deviation and hunting effect resulted from single phase application on unbalanced loads.

  • Voltage stability regulation: From no load to full load the voltage difference will notexceed ±1%.

  • Voltage adjustable range: ±5% of rated voltage.
  • Frequency variation: will not exceed ±0.5%。of its mean value for constant load.
  • Frequency stability regulation: From no load to full load,frequency variation shall be:
     A. Less than 5%(Engine with mechanical governor)
     B. Less than 1%(Engine with electric governor).
  • Transient voltage variation: Generator set is equipped with automatic voltage regulator when the load decreases suddenly from full load to no load in the operation under rated speed,rated voltage condition, the voltage leap of the terminals shall not exceed 30% of the rated voltage and shall restore to+/-2.5% of the rated voltage within 2 seconds. (+/-3% of the rated voltage if the generator set is for standby use) When the load increases suddenly from no load to 67% of the rated current at 0.4 power factor, the voltage dip of the terminals shall not exceed 25% of the rated voltage and restore to +/-2.5% of the rated voltage within 2 secondss.
    ‧ Waveform Distortion: Less than 6%.

    ‧ Harmonic Distortion: Less than 6%.

    ‧ Telephone Influence Factor: Less than 50 per NEMA MGI-22.43.

  •  Daily tank
  • Batteries
  • Battery charger
  • lndustrial grade exhaust silencer
  • Exhaust flexible pipe
  • Rubber plate isolators
  • Tool box
  • Operation manual

  • Engine
    Electric governor, Jacket water preheater, Water oil separator, Critical-grade exhaust silencer, Maintenance free batteries, Ni-Cd batteries

    Control panel
    Space heater, Floor standing panel, Low coolant level alarm, Low fuel level alarm, Over/Under voltage alarm, Buzzer, Over load, Panel light, AC voltage adjust, Watt meter, Watt hour meter, Power factor meter

    Alternator
    Remote radiator/Hot well system, Cooling tower/Heat exchanger, Weather-protective enclosure, Soundproof enclosure, Trailer, Main line circuit breaker, Spring type isolators, Automatic transfer switch, Parallel operation device, Export box package, Exhaust clear system, Flame arrester, Fuel pump of fuel tank, SUS daily fuel tank

    Generator Set
    The engine generator set can be tailored and designed to meet client s requirements and specifications.

    The engine generator set can be tailored and designed to meet client s requirements and specifications.

MTU CUMMINS PERKINS DOOSAN
 
FPT VOLVO PENTA 性能與配件